Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Clin Infect Dis ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466039

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

2.
Heart Rhythm ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38466251

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38466252

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

5.
Heart Rhythm O2 ; 5(2): 131-136, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38545321

RESUMO

Background: Respiratory motion management strategies are used to minimize the effects of breathing on the precision of stereotactic ablative radiotherapy for ventricular tachycardia, but the extent of cardiac contractile motion of the human heart has not been systematically explored. Objective: We aim to assess the magnitude of cardiac contractile motion between different directions and locations in the heart. Methods: Patients with intracardiac leads or valves who underwent 4-dimensional cardiac computed tomography (CT) prior to a catheter ablation procedure for atrial or ventricular arrhythmias at 2 medical centers were studied retrospectively. The displacement of transvenous right atrial appendage, right ventricular (RV) implantable cardioverter-defibrillator, coronary sinus lead tips, and prosthetic cardiac devices across the cardiac cycle were measured in orthogonal 3-dimensional views on a maximal-intensity projection CT reconstruction. Results: A total of 31 preablation cardiac 4-dimensional cardiac CT scans were analyzed. The LV lead tip had significantly greater motion compared with the RV lead in the anterior-posterior direction (6.0 ± 2.2 mm vs 3.8 ± 1.7 mm; P = .01) and superior-inferior direction (4.4 ± 2.9 mm vs 3.5 ± 2.0 mm; P = .049). The prosthetic aortic valves had the least movement of all fiducials, specifically compared with the RV lead tip in the left-right direction (3.2 ± 1.2 mm vs 6.1 ± 3.8 mm, P = .04) and the LV lead tip in the anterior-posterior direction (3.8 ± 1.7 mm vs 6.0 ± 2.2 mm, P = .03). Conclusion: The degree of cardiac contractile motion varies significantly (1 mm to 15.2 mm) across different locations in the heart. The effect of contractile motion on the precision of radiotherapy should be assessed on a patient-specific basis.

6.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38472038

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Assuntos
Infecções Cardiovasculares , Endocardite , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Consenso , Tomografia Computadorizada por Raios X , Imagem Multimodal , Endocardite/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
10.
J Cardiovasc Electrophysiol ; 35(2): 240-246, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047465

RESUMO

INTRODUCTION: The pivotal study of the extravascular implantable cardioverter-defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient-reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. METHODS: The EV ICD Pivotal Study was a prospective, single-arm, nonrandomized, global, premarket approval trial. Patients completed the 12-Item Short Form Survey (SF-12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. RESULTS: From baseline to 6 months, patients within the EV ICD Pivotal Study (n = 247) reported statistically significant SF-12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV-ICD or S-ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S-ICD and 73.0 ± 17.4, p = .004 for TV-ICD). CONCLUSION: The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6-month follow-up and markedly better overall acceptance of their ICD compared to a previous study with S-ICD and TV-ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.


Assuntos
Desfibriladores Implantáveis , Humanos , Qualidade de Vida , Estudos Prospectivos , Inquéritos e Questionários , Medidas de Resultados Relatados pelo Paciente
11.
J Cardiovasc Electrophysiol ; 35(2): 230-237, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047467

RESUMO

INTRODUCTION: The extravascular implantable cardioverter defibrillator (EV ICD) has extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries. METHODS: Battery longevity data were modeled using a Markov model from averages reported in device labeling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. RESULTS: Average modeled battery longevity was determined to be 7.3 years for the S-ICD versus 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to S-ICD and a 24.3%-26.0% reduction in cost. A one-way sensitivity analysis of the model for the US healthcare system found that use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with five-figure cost savings in all scenarios ($18 602-$40 948). CONCLUSION: The longer projected battery life of the EV ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.


Assuntos
Desfibriladores Implantáveis , Humanos , Falha de Equipamento , Cardioversão Elétrica/efeitos adversos , Previsões , Redução de Custos
12.
Heart Rhythm O2 ; 4(10): 599-608, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37936671

RESUMO

Background: Pulsed field ablation (PFA) has emerged as a novel energy source for the ablation of atrial fibrillation (AF) using ultrarapid electrical pulses to induce cell death via electroporation. Objective: The purpose of this study was to compare the safety and acute efficacy of ablation for AF with PFA vs thermal energy sources. Methods: We performed an extensive literature search and systematic review of studies that evaluated the safety and efficacy of ablation for AF with PFA and compared them to landmark clinical trials for ablation of AF with thermal energy sources. Freeman-Tukey double arcsine transformation was used to establish variance of raw proportions followed by the inverse with the random-effects model to combine the transformed proportions and generate the pooled prevalence and 95% confidence interval (CI). Results: We included 24 studies for a total of 5203 patients who underwent AF ablation. Among these patients, 54.6% (n = 2842) underwent PFA and 45.4% (n = 2361) underwent thermal ablation. There were significantly fewer periprocedural complications in the PFA group (2.05%; 95% CI 0.94-3.46) compared to the thermal ablation group (7.75%; 95% CI 5.40-10.47) (P = .001). When comparing AF recurrence up to 1 year, there was a statistically insignificant trend toward a lower prevalence of recurrence in the PFA group (14.24%; 95% CI 6.97-23.35) compared to the thermal ablation group (25.98%; 95% CI 15.75-37.68) (P = .132). Conclusion: Based on the results of this meta-analysis, PFA was associated with lower rates of periprocedural complications and similar rates of acute procedural success and recurrent AF with up to 1 year of follow-up compared to ablation with thermal energy sources.

13.
Artigo em Inglês | MEDLINE | ID: mdl-37855992

RESUMO

BACKGROUND: Pulsed field ablation (PFA) induces cell death through electroporation using ultrarapid electrical pulses. We sought to compare the procedural efficiency characteristics, safety, and efficacy of ablation of atrial fibrillation (AF) using PFA compared with thermal energy ablation. METHODS: We performed an extensive literature search and systematic review of studies that compared ablation of AF with PFA versus thermal energy sources. Risk ratio (RR) 95% confidence intervals (CI) were measured for dichotomous variables and mean difference (MD) 95% CI were measured for continuous variables, where RR < 1 and MD < 0 favor the PFA group. RESULTS: We included 6 comparative studies for a total of 1012 patients who underwent ablation of AF: 43.6% with PFA (n = 441) and 56.4% (n = 571) with thermal energy sources. There were significantly shorter procedures times with PFA despite a protocolized 20-min dwell time (MD - 21.95, 95% CI - 33.77, - 10.14, p = 0.0003), but with significantly longer fluroscopy time (MD 5.71, 95% CI 1.13, 10.30, p = 0.01). There were no statistically significant differences in periprocedural complications (RR 1.20, 95% CI 0.59-2.44) or recurrence of atrial tachyarrhythmias (RR 0.64, 95% CI 0.31, 1.34) between the PFA and thermal ablation cohorts. CONCLUSIONS: Based on the results of this meta-analysis, PFA was associated with shorter procedural times and longer fluoroscopy times, but no difference in periprocedural complications or rates of recurrent AF when compared to ablation with thermal energy sources. However, larger randomized control trials are needed.

14.
J Arrhythm ; 39(5): 681-756, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799799

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.

17.
Heart Rhythm ; 20(9): e17-e91, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37283271

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Criança , Humanos , Fascículo Atrioventricular , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Eletrocardiografia/métodos
18.
Heart Rhythm ; 20(8): 1111-1118, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37075957

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) safety in patients with an epicardial cardiac implantable electronic device (CIED) is uncertain. OBJECTIVE: The purpose of this study was to assess the safety and adverse effects of MRI in patients who had surgically implanted epicardial CIED. METHODS: Patients with surgically implanted CIEDs who underwent MRI with an appropriate cardiology-radiology collaborative protocol between January 2008 and January 2021 were prospectively studied in 2 clinical centers. All patients underwent close cardiac monitoring through MRI procedures. Outcomes were compared between the epicardial CIED group and the matched non-MRI-conditional transvenous CIED group. RESULTS: Twenty-nine consecutive patients with epicardial CIED (41.4% male; mean age 43 years) underwent 52 MRIs in 57 anatomic regions. Sixteen patients had a pacemaker, 9 had a cardiac defibrillator or cardiac resynchronization therapy-defibrillator, and 4 had no device generator. No significant adverse events occurred in the epicardial or transvenous CIED groups. Battery life, pacing, sensing thresholds, lead impedance, and cardiac biomarkers were not significantly changed, except 1 patient had a transient decrease in atrial lead sensing function. CONCLUSION: MRI of CIEDs with epicardially implanted leads does not represent a greater risk than transvenous CIEDs when performed with a multidisciplinary collaborative protocol centered on patient safety.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Adulto , Feminino , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Coração , Segurança do Paciente
19.
PLoS One ; 18(3): e0281340, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36917566

RESUMO

INTRODUCTION: The wearable cardioverter defibrillator (WCD) is used to protect patients at risk for sudden cardiac arrest. We examined defibrillation efficacy and safety of a biphasic truncated exponential waveform designed for use in a contemporary WCD in three animal studies and a human study. METHODS: Animal (swine) studies: #1: Efficacy comparison of a 170J BTE waveform (SHOCK A) to a 150J BTE waveform (SHOCK B) that approximates another commercially available waveform. Primary endpoint first shock success rate. #2: Efficacy comparison of the two waveforms at attenuated charge voltages in swine at three prespecified impedances. Primary endpoint first shock success rate. #3: Safety comparison of SHOCK A and SHOCK B in swine. Primary endpoint cardiac biomarker level changes baseline to 6 and 24 hours post-shock. Human Study: Efficacy comparison of SHOCK A to prespecified goal and safety evaluation. Primary endpoint cumulative first and second shock success rate. Safety endpoint adverse events. RESULTS: Animal Studies #1: 120 VF episodes in six swine. First shock success rates for SHOCK A and SHOCK B were 100%; SHOCK A non-inferior to SHOCK B (entire 95% CI of rate difference above -10% margin, p < .001). #2: 2,160 VF episodes in thirty-six swine. Attenuated SHOCK A was non-inferior to attenuated SHOCK B at each impedance (entire 95% CI of rate difference above -10% margin, p < .001). #3: Ten swine, five shocked five times each with SHOCK A, five shocked five times each with SHOCK B. No significant difference in troponin I (p = 0.658) or creatine phosphokinase (p = 0.855) changes from baseline between SHOCK A and SHOCK B. Human Study: Thirteen patients, 100% VF conversion rate. Mild skin irritation from adhesive defibrillation pads in three patients. CONCLUSIONS: The BTE waveform effectively and safely terminated induced VF in swine and a small sample in humans. TRIAL REGISTRATION: Human study clinical trial registration: URL: https://clinicaltrials.gov; Unique identifier: NCT04132466.


Assuntos
Fibrilação Ventricular , Dispositivos Eletrônicos Vestíveis , Humanos , Suínos , Animais , Fibrilação Ventricular/terapia , Resultado do Tratamento , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Desfibriladores
20.
Heart Rhythm ; 20(6): 863-871, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36842610

RESUMO

BACKGROUND: Whether conduction system pacing (CSP) is an alternative option for cardiac resynchronization therapy (CRT) in patients with heart failure remains an area of active investigation. OBJECTIVE: The purpose of this study was to assess the echocardiographic and clinical outcomes of CSP compared to biventricular pacing (BiVP). METHODS: This multicenter retrospective study included patients who fulfilled CRT indications and received CSP. Patients with CSP were matched using propensity score matching and compared in a 1:1 ratio to patients who received BiVP. Echocardiographic and clinical outcomes were assessed. Response to CRT was defined as an absolute increase of ≥5% in left ventricular ejection fraction (LVEF) at 6 months post-CRT. RESULTS: A total of 238 patients were included. Mean age was 69.8 ± 12.5 years, and 66 (27.7%) were female. Sixty-nine patients (29%) had His-bundle pacing, 50 (21%) had left bundle branch area pacing, and 119 (50%) had BiVP. Mean follow-up duration in the CSP and BiVP groups was 269 ± 202 days and 304 ± 262 days, respectively (P = .293). The proportion of CRT responders was greater in the CSP group than in the BiVP group (74% vs 60%, respectively; P = .042). On Kaplan-Meier analysis, there was no statistically significant difference in the time to first heart failure hospitalization (log-rank P = .78) and overall survival (log-rank P = .68) between the CSP and BiVP groups. CONCLUSION: In patients with heart failure and reduced ejection fraction, CSP resulted in greater improvement in LVEF compared to BiVP. Large-scale randomized trials are needed to validate these outcomes and further investigate the different options available for CSP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Terapia de Ressincronização Cardíaca/métodos , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda/fisiologia , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Eletrocardiografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...